Skip to content

Room-capture analysis

Privacy boundary

The original capture is kept only under the Git-ignored local/captures/ directory. Printed serials, CoreBluetooth identifiers, device names, exact raw packets, and firmware metadata are intentionally absent from tracked files and package distributions.

The public parser fixture at tests/fixtures/observed-c3-synthetic.json is a synthetic packet constructed to exercise the independently observed byte pattern. It is not represented as an authentic over-the-air packet.

Sanitized result

Targeted scans observed one T&D advertiser. The reported room inventory was 505B, 507, and 502, but the printed label of the transmitting unit and the RTR505B input module were not recorded alongside the packet. The third serial byte was C3, and two 16-bit candidate words changed consistently across observations.

That context is useful for planning another capture, but it does not prove that every C3 serial is an RTR505B or identify a physical conversion. The parser therefore exposes the family and bytes without assigning a model or readings.

Other reported units

If 502 and 507 mean legacy RTR-502 and RTR-507 without a trailing B, they do not provide this BLE transport. If either label actually ends in B, its BLE state, registration, battery, and range need to be checked before drawing a protocol conclusion.

The library will not add 429 MHz radio, optical, or base-unit transports. Only BLE advertisements are in scope.

Required follow-up capture

Before adding an RTR500B decoder:

  1. photograph or transcribe the exact logger and input-module labels;
  2. record firmware and configuration mode;
  3. record the on-device or trusted reference value at the same time;
  4. collect repeated advertisements while the input changes;
  5. test invalid/disconnected sensor behavior; and
  6. sanitize identifiers before committing fixtures.